instruments:mfrsr:mfrsr
This is an old revision of the document!
Table of Contents
Multi-Filter Rotating Shadowband Radiometer
Mentor: K. Ebell
Principle
Instrument
YES Inc. MFR-7
at Forschungszentrum Jülich on the roof of the IEK-8 (Institut für Energie- und Klimaforschung: Troposphäre).
Data
- If you are interested in receiving data please contact the instrument mentors: K. Ebell
Current measurements:
<html>
<a href="http://gop.meteo.uni-koeln.de/~hatpro/jue/VAPs/radar_mwr/latest_l2_radar_lwp.png" target="_blank"> <img src="http://gop.meteo.uni-koeln.de/~hatpro/jue/VAPs/radar_mwr/latest_l2_radar_lwp.png" width=300> </a> click to enlarge
</html>
The figure shows the LWP from the HATPRO MWR as well as radar reflectivity factor, linear depolarization ratio, Doppler velocity and Doppler spectral width of MIRA zenith measurements.
Gray areas indicate no data.
History
Period | Place | Project |
---|---|---|
06/07/2015 - today | Research Center Jülich, Germany | JOYCE |
Specifications
Parameter | Specification | Remark |
---|---|---|
Wavelengths | broadband, 415, 500, 615, 673, 870, 940 nm | Silicon pyranometer for broadband measurements. |
FWHM bandwidth | 10 nm | |
Cosine response | Better than 5% for 0 - 80° zenith angle; better than 1% with corrections | |
Manufacturer | YES Inc. |
instruments/mfrsr/mfrsr.1436790063.txt.gz · Last modified: 2016/04/07 19:53 (external edit)