 **HATPRO** (//Humidity and Temperature Profiler//) is a microwave radiometer [[http://en.wikipedia.org/wiki/Remote_sensing|remote sensing]] instrument detecting thermal emission from the [[http://en.wikipedia.org/wiki/Atmosphere| atmosphere]]. We currently operate three HATPRO devices: **HATPRO** (//Humidity and Temperature Profiler//) is a microwave radiometer [[http://en.wikipedia.org/wiki/Remote_sensing|remote sensing]] instrument detecting thermal emission from the [[http://en.wikipedia.org/wiki/Atmosphere| atmosphere]]. We currently operate three HATPRO devices:
 +  * [[instruments:foghat:foghat|FOGHAT]] in [[sites:iquique|Iquique]] in the Atacama desert
   * [[instruments:tophat:tophat|TOPHAT]] at [[sites:joyce|JOYCE]] near (Julich)   * [[instruments:tophat:tophat|TOPHAT]] at [[sites:joyce|JOYCE]] near (Julich)
 +  * [[instruments:snohat:snohat|SNOHAT]] at the [[sites:ufs|Schneefernerhaus observatory]] (Mt. Zugspitze)
   * [[instruments:sunhat:sunhat|SUNHAT]] on [[sites:barbados|Barbados]]   * [[instruments:sunhat:sunhat|SUNHAT]] on [[sites:barbados|Barbados]]
-  * [[instruments:snohat:snohat|SNOHAT]] at the [[sites:ufs|Schneefernerhaus observatory]] (Mt. Zugspitze) 
  
 ===== Introduction ===== ===== Introduction =====
- 
 Microwave radiometers are very sensitive receivers designed to measure thermal electromagnetic radiation emitted by material media like the atmosphere. They are usually equipped with multiple receiving channels in order to derive the characteristic emission spectrum of the atmosphere or extraterrestrial objects. Microwave radiometers are utilized in a variety of environmental and engineering applications, including weather forecasting, climate monitoring, [[https://en.wikipedia.org/wiki/Radio_astronomy|radio astronomy]] and radio propagation studies.  Microwave radiometers are very sensitive receivers designed to measure thermal electromagnetic radiation emitted by material media like the atmosphere. They are usually equipped with multiple receiving channels in order to derive the characteristic emission spectrum of the atmosphere or extraterrestrial objects. Microwave radiometers are utilized in a variety of environmental and engineering applications, including weather forecasting, climate monitoring, [[https://en.wikipedia.org/wiki/Radio_astronomy|radio astronomy]] and radio propagation studies. 
  
Line 14: Line 14:
 {{:instruments:sunhat:p1040071.jpg?400|}} \\ {{:instruments:sunhat:p1040071.jpg?400|}} \\
  
-[[http://www.radiometer-physics.de/rpg/html/Home.html|RPG]] HATPRO-SUNHAT at the [[http://barbados.zmaw.de|Barbados Clouds Observatory]].+Fig. 1: [[http://www.radiometer-physics.de/rpg/html/Home.html|Humitity and Temperature Profiler]] (HATPRO-SUNHATat the [[http://barbados.zmaw.de|Barbados Clouds Observatory]].
  
 ===== History of microwave radiometer measurements ===== ===== History of microwave radiometer measurements =====
 First developments of microwave radiometer were dedicated to the measurement of radiation of extraterrestrial origin in the 1930s and 1940s [1]. The first operational microwave radiometer was designed by [[https://en.wikipedia.org/wiki/Robert_H._Dicke|Robert H. Dicke]] in the Radiation Laboratory of Massachusetts Institute of Technology to better determine the temperature of the microwave background radiation. This first radiometer worked at a wavelength 1.25 cm and was operated at the Massachusetts Institute of Technology. Dicke also first discovered weak atmospheric absorption in the MW using three different radiometers (at wavelengths of 1.0, 1.25 and 1.5 cm).  First developments of microwave radiometer were dedicated to the measurement of radiation of extraterrestrial origin in the 1930s and 1940s [1]. The first operational microwave radiometer was designed by [[https://en.wikipedia.org/wiki/Robert_H._Dicke|Robert H. Dicke]] in the Radiation Laboratory of Massachusetts Institute of Technology to better determine the temperature of the microwave background radiation. This first radiometer worked at a wavelength 1.25 cm and was operated at the Massachusetts Institute of Technology. Dicke also first discovered weak atmospheric absorption in the MW using three different radiometers (at wavelengths of 1.0, 1.25 and 1.5 cm). 
  
-Soon after satellites were first used for observing the atmosphere, MW radiometers became part of their instrumentation. In 1962 the [[https://en.wikipedia.org/wiki/Mariner_2|Mariner-2 mission]] was launched by NASA in order to investigate the surface of Venus including a MW radiometer for water vapor and temperature observations. In following years a wide variety of MW radiometers were tested on satellites. The launch of the [[https://en.wikipedia.org/wiki/Scanning_multichannel_microwave_radiometer|Scanning Multichannel Microwave Radiometer]] (SMMR) in 1978 became an important milestone in the history of radiometry. It was the first time a conically scanning radiometer was used in space; it was brought in space on board of the NASA [[https://en.wikipedia.org/wiki/Nimbus_program|Nimbus satellite]] [4]. The launch of this mission gave the opportunity to image the Earth at a constant angle of incidence that is important as surface emissivity is angular dependent. In the beginning of 1980, new multi-frequency, dual-polarization radiometric instruments were developed. Two spacecraft were launched which carried instruments of this type: Nimbus-7 and [[https://en.wikipedia.org/wiki/Seasat|Seasat]]. The Nimbus-7 mission results allowed to globally monitor the state of ocean surface as well as surface covered by snow and glaciers. Today, radiometers are widely used not only onboard different satellites but also as ground-based instruments integrated in worldwide observational networks.+Soon after satellites were first used for observing the atmosphere, MW radiometers became part of their instrumentation. In 1962 the [[https://en.wikipedia.org/wiki/Mariner_2|Mariner-2 mission]] was launched by NASA in order to investigate the surface of Venus including a MW radiometer for water vapor and temperature observations. In following years a wide variety of MW radiometers were tested on satellites. The launch of the [[https://en.wikipedia.org/wiki/Scanning_multichannel_microwave_radiometer|Scanning Multichannel Microwave Radiometer]] (SMMR) in 1978 became an important milestone in the history of radiometry. It was the first time a conically scanning radiometer was used in space; it was brought in space on board of the NASA [[https://en.wikipedia.org/wiki/Nimbus_program|Nimbus satellite]] [4]. The launch of this mission gave the opportunity to image the Earth at a constant angle of incidence that is important as surface emissivity is angular dependent. In the beginning of 1980, new multi-frequency, dual-polarization radiometric instruments were developed. Two spacecraft were launched which carried instruments of this type: Nimbus-7 and [[https://en.wikipedia.org/wiki/Seasat|Seasat]]. The Nimbus-7 mission results allowed to globally monitor the state of ocean surface as well as surface covered by snow and glaciers. Today, microwave instruments like the Advanced Microwave Sounding Unit [[https://en.wikipedia.org/wiki/Advanced_Microwave_Sounding_Unit|AMSU]], Special Sensor Microwave Imager / Sounder [[https://en.wikipedia.org/wiki/SSMIS|SSMIS]] are widely used not only onboard different satellites
 + 
 +Ground-Based radiometer for the determination of temperature profiles were first explores in the 1960s [4] and have since themn strongly improved in terms of reduced noises and the ability to run unattended in 24/7 mode within worldwide observational networks [5]. Review articles [[http://www.ursi.org/files/RSBissues/RSB_310_2004_09.pdf|[6] ]], [7] and a detailed online [[http://cfa.aquila.infn.it/wiki.eg-climet.org/index.php5/Microwave_radiometer|handbook]] [8] are available
  
 Here we could keep the graphic from the original article Here we could keep the graphic from the original article
 https://en.wikipedia.org/wiki/Microwave_radiometer#/media/File:Radiometer_227629main_ostm-AMR-RSA.jpg https://en.wikipedia.org/wiki/Microwave_radiometer#/media/File:Radiometer_227629main_ostm-AMR-RSA.jpg
 +Fig. 2 
  
 =====  Principle of operation =====  =====  Principle of operation ===== 
-Solids, liquids (e.g. the earth's surface, ocean, sea ice, snow, vegetation) but also gases emit and absorb MW radiation. Traditionally, the amount of radiation a microwave radiometer receives is expressed as the equivalent blackbody temperature also called [[https://en.wikipedia.org/wiki/Brightness_temperature|brightness temperature]] (TB). The atmospheric components emit and absorb MW radiation in different ways: Atmospheric gases provide specific absorption features (Fig. 1) which allow to derive information about their vertical profile. Examples for such absorption features are the oxygen absorption complex (caused by magnetic dipole transitions) around 60 GHz which is used to derive temperature profiles or the water vapor absorption line around 22.235 GHz (dipole rotational transition) which is used to observe the vertical profile of humidity. Other significant absorption lines are found at 118.75 GHz (oxygen absorption) and at 183.31 GHz (water vapor absorption, used for water vapor profiling under dry conditions or from satellite). Weak absorption features due to ozone are also used for stratospheric [[http://link.springer.com/article/10.1023%2FA%3A1010406601571|ozone density and temperature]] profiling [7].+Solids, liquids (e.g. the earth's surface, ocean, sea ice, snow, vegetation) but also gases emit and absorb MW radiation. Traditionally, the amount of radiation a microwave radiometer receives is expressed as the equivalent blackbody temperature also called [[https://en.wikipedia.org/wiki/Brightness_temperature|brightness temperature]] (TB). In the microwave range several atmospheric gases inhibit [[https://en.wikipedia.org/wiki/Rotational_spectroscopy|rotational lines]]. They provide specific absorption features (Fig. 3) which allow to derive information about their abundance and vertical structure. Examples for such absorption features are the oxygen absorption complex (caused by magnetic dipole transitions) around 60 GHz which is used to derive temperature profiles or the water vapor absorption line around 22.235 GHz (dipole rotational transition) which is used to observe the vertical profile of humidity. Other significant absorption lines are found at 118.75 GHz (oxygen absorption) and at 183.31 GHz (water vapor absorption, used for water vapor profiling under dry conditions or from satellite). Weak absorption features due to ozone are also used for stratospheric [[http://link.springer.com/article/10.1023%2FA%3A1010406601571|ozone density and temperature]] profiling.
  
-The emission and absorption of hydrometeors does not provide characteristic absorption line features as found for atmospheric gases. Liquid hydrometeors (small cloud and rizzle drops) are efficient emitters in the microwave. Besides the distinct absorption features of molecular transistion lines, there are also contributions of so-called „continuum“ absorbers in the microwave region as the water vapor continuum and the liquid water continuum. The latter is only present if a cloud is present in the field of view of the MWR, hence, measuring at two frequencies, one close to the water absorption line (22.235 GHz) and one in the nearby window region (typically 31 GHz) provides information on both the columnar amount of water vapor and the columnar amount of liquid water separately (two-channel radiometer).+Besides the distinct absorption features of molecular transistion lines, there are also non-resonant contributions by hydrometeors (liquid drops and frozen particles). Liquid water emission increases with frequency, hence, measuring at two frequencies, typically one close to the water absorption line (22.235 GHz) and one in the nearby window region (typically 31 GHz) dominated by liquid absorption provides information on both the columnar amount of water vapor and the columnar amount of liquid water separately (two-channel radiometer). The so-called „water vapor continuum“ is arises from the contribution of far away water vapor lines.
  
-Larger rain drops as well as larger frozen hydrometeors (snow, graupel, hail) also scatter microwave radiation especially at higher frequencies (>90 GHz). These scattering effects can be used to distinguish between rain and cloud water content [10] but also to constrain the columnar amount of snow and ice particles from space [11] and from the ground [12].+Larger rain drops as well as larger frozen hydrometeors (snow, graupel, hail) also scatter microwave radiation especially at higher frequencies (>90 GHz). These scattering effects can be used to distinguish between rain and cloud water content exploitinh polarized measurements [9] but also to constrain the columnar amount of snow and ice particles from space [10] and from the ground [11].
  
- +{{:instruments:hatpro:mwr_5.png?600|Microwave spectrum: The black lines show the simulated spectrum (in brightness temperatures TB) for a ground-based receiver; the colored lines are the spectrum obtained from a satellite instrument over the ocean measuring at horizontal (blue) and vertical (red) linear polarization. Solid lines indicate simulations for clear-sky (cloud-free) conditions, dotted lines show a clear-sky case with a single layer liquid cloud. The vertical lines indicate typical frequencies used by satellite sensors like the [[https://en.wikipedia.org/wiki/Advanced_Microwave_Sounding_Unit|AMSU]] radiometer.}} \\ 
-{{ :instruments:hatpro:mwr_5.png?600 |Microwave spectrum: The black lines show the simulated spectrum (in brightness temperatures TB) for a ground-based receiver; the colored lines are the spectrum obtained from a satellite instrument over the ocean measuring at horizontal (blue) and vertical (red) linear polarization. Solid lines indicate simulations for clear-sky (cloud-free) conditions, dotted lines show a clear-sky case with a single layer liquid cloud. The vertical lines indicate typical frequencies used by satellite sensors like the [[https://en.wikipedia.org/wiki/Advanced_Microwave_Sounding_Unit|AMSU]] radiometer.}} \\ +Fig. 3: Microwave spectrum: The black lines show the simulated spectrum (in brightness temperatures TB) for a ground-based receiver; the colored lines are the spectrum obtained from a satellite instrument over the ocean measuring at horizontal (blue) and vertical (red) linear polarization. Solid lines indicate simulations for clear-sky (cloud-free) conditions, dotted lines show a clear-sky case with a single layer liquid cloud. The vertical lines indicate typical frequencies used by satellite sensors like the [[https://en.wikipedia.org/wiki/Advanced_Microwave_Sounding_Unit|AMSU]] radiometer.
-Microwave spectrum: The black lines show the simulated spectrum (in brightness temperatures TB) for a ground-based receiver; the colored lines are the spectrum obtained from a satellite instrument over the ocean measuring at horizontal (blue) and vertical (red) linear polarization. Solid lines indicate simulations for clear-sky (cloud-free) conditions, dotted lines show a clear-sky case with a single layer liquid cloud. The vertical lines indicate typical frequencies used by satellite sensors like the [[https://en.wikipedia.org/wiki/Advanced_Microwave_Sounding_Unit|AMSU]] radiometer.+
  
 ===== Design ===== ===== Design =====
 +A microwave radiometer consits of an antenna system, microwave radiofrequency components (frontend) and a backend for signal processing at intermediate frequencies (Fig. 5). The atmospheric signal is very weak and the signal needs to be amplified by around 80 dB. Therefore often heteorodyne techniques are used to convert the signal down to lower frequencies that allow the ise of commercial amplifiers and signal processing. Increasingly low noise amplifiers become available at higher frequencies, i.e. up to 100 GHz, making heteorodyne techniques obsolete. Thermal stabilization is highly important to avoid receiver drifts.
 + 
 +Usually ground-based radiometers are also equipped with environmental sensors (rain, temperature, humidity) and GPS receivers (time and location reference). The antenna itself often measures through a window made of foam which is transparent in the MW (light blue material in Fig. 1) in order to keep the antenna clean of dust, liquid water and ice. Often, also a heated blower system is attached the radiometer which helps to keep the window free of liquid drops or dew (strong emitters in the MW) but also free of ice and snow.
  
-The principal components of a microwave radiometer often follow a similar design and can be grouped into: antenna system, microwave radio-thermal receiver, recording and storage devices and a final processing unit. Usually ground-based radiometers are also equipped with environmental sensors (rain, temperature, humidity) and GPS receivers (time and location reference). The antenna itself often measures through a window made of foam which is transparent in the MW (light blue material in Fig. 1) in order to keep the antenna clean of dust, liquid water and ice. Often, also a heated blower system is attached the radiometer which helps to keep the window free of liquid drops or dew (strong emitters in the MW) but also free of ice and snow. +{{:stuff:mwr_design.png|Schematic diagram of a microwave radiometer}} \\ 
- +Fig. 4: Schematic diagram of a microwave radiometer using the [[https://en.wikipedia.org/wiki/Heterodyne|heterodyne]] principle. 
-{{ :instruments:hatpro:mwr_4.png?400 |Schematic diagram of a microwave radiometer [8].}} \\ +After being received at the antenna the radiofrequency signal is downconverted to the intermediate frequency (IF) with the help of a stable local oscillator signal. After amplification with a Low Noise Amplifier (LNA) and band pass filtering the signal can be detected in full power mode, by splitting or splitting it into multiple frequency bands with a spectrometer. For high-frequency calibrations a Dicke switch is used here.
-Schematic diagram of a microwave radiometer [8].+
  
 ===== Calibration ===== ===== Calibration =====
- 
 The calibration of MWRs sets the basis for accurate measured TB and therefore, for accurate retrieved atmospheric parameters as temperature profiles, integrated water vapor and liquid water path. The simplest version of a calibation is a so-called „hot-cold“ calibration using two reference blackbodies at known, but different, „hot“ and „cold“ temperatures, i.e. assuming a linear relation between input power and output voltage of the detector. Knowing the physical temperatures of the references, their TB can be calculated and directly related to detected voltages of the radiometer, hence, the linear relationship between TB and voltages can be obtained. The calibration of MWRs sets the basis for accurate measured TB and therefore, for accurate retrieved atmospheric parameters as temperature profiles, integrated water vapor and liquid water path. The simplest version of a calibation is a so-called „hot-cold“ calibration using two reference blackbodies at known, but different, „hot“ and „cold“ temperatures, i.e. assuming a linear relation between input power and output voltage of the detector. Knowing the physical temperatures of the references, their TB can be calculated and directly related to detected voltages of the radiometer, hence, the linear relationship between TB and voltages can be obtained.
  
-The temperatures of the calibration targets should be chosen such that they span the full measurement range. Ground-based radiometers usually use an ambient temperature target as „hot“ reference. As a cold target one can use either a liquid nitrogen cooled blackbody (77 K) [e.g. Ulaby] or a zenith clear sky TB that was obtained indirectly from radiative transfer theory [Paper Westwater]. Satellites use a heated target as „hot“ reference and the cosmic background radiation as „cold“ reference. To increase the accuracy and stabiltity of MWR calibrations further calibration targets, such as internal noise sources, can be used.+The temperatures of the calibration targets should be chosen such that they span the full measurement range. Ground-based radiometers usually use an ambient temperature target as „hot“ reference. As a cold target one can use either a liquid nitrogen cooled blackbody (77 K) [1] or a zenith clear sky TB that was obtained indirectly from radiative transfer theory [Paper Westwater]. Satellites use a heated target as „hot“ reference and the cosmic background radiation as „cold“ reference. To increase the accuracy and stabiltity of MWR calibrations further calibration targets, such as internal noise sources, or Dicke switches (Fig. 4) can be used. 
 =====   Retrieval of temperature and water vapor profiles   ===== =====   Retrieval of temperature and water vapor profiles   =====
- 
 The retrieval of physical quantities (e.g. temperature or water vapor profiles) is not straight-forward and comprehensive retrieval algorithms (using inversion techniques like [[https://en.wikipedia.org/wiki/Optimal_estimation|optimal estimation]] approach) have been developed. The retrieval of physical quantities (e.g. temperature or water vapor profiles) is not straight-forward and comprehensive retrieval algorithms (using inversion techniques like [[https://en.wikipedia.org/wiki/Optimal_estimation|optimal estimation]] approach) have been developed.
  
Line 72: Line 75:
 [2] Thermal Microwave Radiation: Applications for Remote Sensing, C. Matzler, 2006, The Institution of Engineering and Technology, London, Chapter 1. [2] Thermal Microwave Radiation: Applications for Remote Sensing, C. Matzler, 2006, The Institution of Engineering and Technology, London, Chapter 1.
  
-[3] http://cetemps.aquila.infn.it/mwrnet/main_files/whatisMWRnet.html +[3] Westwater, Edgeworth Rupert, 1970Ground-Based Determination of Temperature Profiles by MicrowavesPH.DThesis, UNIVERSITY OF COLORADO AT BOULDER, Source: Dissertation Abstracts International, Volume: 32-02, Section: B, page: 1134
- +
 [4] Passive Microwave Remote Sensing of the Earth, Physical Foundations, Eugene A. Sharkov, Springer-Praxis Books in Geophysical Sciences, Chapter 14: Passive microwave space missions [4] Passive Microwave Remote Sensing of the Earth, Physical Foundations, Eugene A. Sharkov, Springer-Praxis Books in Geophysical Sciences, Chapter 14: Passive microwave space missions
  
-  - Cimini et al., 2009 +[5] http://cetemps.aquila.infn.it/mwrnet/main_files/whatisMWRnet.html 
-  Klein and Gasiewski2000 + 
-  Eugene ASharkov“Passive Microwave Remote Sensing of the Earth”Physical FoundationsSpringer-Praxis Books in Geophysical Sciences, Chapter 3: Microwave radiometers: functionsdesignconcepts, characteristics [http://www.iki.rssi.ru/asp/pub_sha1/pub_sha1.htm] (INAKTIVE LINK!) +[6] Westwater, E.R., C. Mätzler, S. Crewell (2004) A review of surface-based microwave and millimeter-wave radiometric remote sensing of the troposphere. Radio Science BulletinNo. 3010, September 2004, 59-80, 
-  http://fas.org/irp/imint/docs/rst/Sect14/Sect14_4.html + 
-  Czekala et al., Discrimination of cloud and rain liquid water path by groundbased polarized microwave radiometry, GRL, 2001, DOI: 10.1029/2000GL012247 +[7] Westwater, E. R., S. Crewell, C. Mätzler, and D. Cimini, 2006: Principles of Surface-based Microwave and Millimeter wave Radiometric Remote Sensing of the TroposphereQuaderni Della Societa Italiana di Elettromagnetismo1(3)September 200550-90.  
-  Bennartz, R., and P. Bauer (2003), Sensitivity of microwave radiances at 85–183 GHz to precipitating ice particles, Radio Sci., 38(4), 8075, doi:10.1029/2002RS002626. + 
-  Kneifel et al., Snow scattering signals in ground-based passive microwave radiometer measurements, JGR, 2010, DOI: 10.1029/2010JD013856+[8] Final report of the COST action EG-Climet, http://cfa.aquila.infn.it/wiki.eg-climet.org/index.php5/Microwave_radiometer 
 + 
 +[9] Czekala et al. (2001), Discrimination of cloud and rain liquid water path by groundbased polarized microwave radiometry, Geophy. Res. Lett., DOI: 10.1029/2000GL012247 
 + 
 +[10] Bennartz, R., and P. Bauer (2003), Sensitivity of microwave radiances at 85–183 GHz to precipitating ice particles, Radio Sci., 38(4), 8075, doi:10.1029/2002RS002626. 
 + 
 +[11] Kneifel et al. (2010), Snow scattering signals in ground-based passive microwave radiometer measurements, J. Geophys. Res., DOI: 10.1029/2010JD013856 
 + 
  
   
instruments/hatpro/hatpro.txt · Last modified: 2021/01/22 22:17 by 127.0.0.1