instruments:pvm:pvm
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
instruments:pvm:pvm [2016/10/14 12:11] – [PVM - Photovoltaic Modules] cfrank | instruments:pvm:pvm [2020/08/31 21:59] – [History] bernhard | ||
---|---|---|---|
Line 15: | Line 15: | ||
===== Principle - Photovoltaic ===== | ===== Principle - Photovoltaic ===== | ||
- | Photovoltaic modules convert | + | Photovoltaic modules convert |
===== Principle - Yield measurements ===== | ===== Principle - Yield measurements ===== | ||
- | In work | + | The I-V curve (current voltage characteristic) of the modules is measured by a progressive increasing of the consumer resistance and simultaneous I-V measurements. The produced energy is released via a radiator. |
===== Instrument ===== | ===== Instrument ===== | ||
{{: | {{: | ||
Line 27: | Line 27: | ||
* Yield measurements with 1 minute temporal resolution | * Yield measurements with 1 minute temporal resolution | ||
- | * If you are interested in receiving | + | * If you are interested in receiving data please contact: [[http:// |
+ | * See [[http:// | ||
===== History ===== | ===== History ===== | ||
- | ^ Period | + | ^ Period |
- | | 5. October 2016 - today | Forschungszentrum Jülich | JOYCE | | + | | 5. October 2016 - 02.01.2017 | 30°, southward | Forschungszentrum Jülich | ET-CC | yes | |
+ | | 03.01.2017 - 10.06.2020 | ||
+ | | 10.06.2020 | ||
+ | | |
instruments/pvm/pvm.txt · Last modified: 2021/01/22 22:17 by 127.0.0.1